datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

CS5127GDWR16 View Datasheet(PDF) - Cherry semiconductor

Part Name
Description
View to exact match
CS5127GDWR16 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Block Diagram
COMP1 VFFB1
VFB1
VREF
VIN
SYNC
RT
CT
VFB2
1.275V
-
Error
Amplifier
+
+
PWM
Comparator
-
VIN
Undervoltage
Lockout
Bandgap
Voltage
Reference
Reference
Undervoltage
Lockout
1.275V
+
Error
Amplifier
-
Oscillator
-
PWM
Comparator
+
Channel 2
Gate Driver
GATE1
LGND
PGND
Channel 2
Gate Driver
GATE2
COMP2 VFFB2
ENABLE
Theory of Operation
The CS5127 is a dual power supply controller that utilizes
the V2ª control method. Two nonsynchronous V2ª buck
regulators can be built using a single controller IC. This IC
is a perfect choice for efficiently and economically provid-
ing core power and I/O power for the latest
high-performance CPUs. Both switching regulators
employ a fixed frequency architecture driven from a
common oscillator circuit.
V2ª Control Method
The V2ª method of control uses a ramp signal generated
by the ESR of the output capacitors. This ramp is propor-
tional to the AC current in the inductor and is offset by the
DC output voltage. V2ª inherently compensates for varia-
tion in both line and load conditions since the ramp signal
is generated from the output voltage. This differs from tra-
ditional methods such as voltage mode control, where an
artificial ramp signal must be generated, and current mode
control, where a ramp is generated from inductor current.
+
PWM
Comparator
-
Ramp Signal
GATE
VFFB
COMP
-
Error
Amplifier
+
Error Signal
VFB
Reference
Voltage
Figure 1: V2ª control diagram.
The V2ª control method is illustrated in Figure 1. Both
the ramp signal and the error signal are generated by the
output voltage. Since the ramp voltage is defined as the
output voltage, the ramp signal is affected by any change
in the output, regardless of the origin of that change. The
ramp signal also contains the DC portion of the output
voltage, allowing the control circuit to drive the output
switch from 0% to about 90% duty cycle.
Changes in line voltage will change the current ramp in
the inductor, affecting the ramp signal and causing the
V2ª control loop to adjust the duty cycle. Since a change
in inductor current changes the ramp signal, the V2ª
method has the characteristics and advantages of current
mode control for line transient response.
Changes in load current will affect the output voltage and
thus will also change the ramp signal. A load step will
immediately change the state of the comparator output
that controls the output switch. In this case, load transient
response time is limited by the comparator response time
and the transition speed of the switch. Notice that the reac-
tion time of the V2ª loop to a load transient is not
dependent on the crossover frequency of the error signal
loop. Traditional voltage mode and current mode methods
are dependent on the compensation of the error signal
loop.
The V2ª error signal loop can have a low crossover fre-
quency, since transient response is handled by the ramp
signal loop. The ÒslowÓ error signal loop provides DC
accuracy. Low frequency roll-off of the error amplifier
bandwidth will significantly improve noise immunity.
This also improves remote sensing of the output voltage,
since switching noise picked up in long feedback traces
can be effectively filtered.
V2ª line and load regulation are dramatically improved
because there are two separate control loops. A voltage
5

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]