PT6301
F. STAND-BY MODE
(Turning off all display-lights and stopped oscillation function)
This mode turns off all display-lights (fixing COM at “Low”) and stops oscillation function.
This completely stops the internal operation of the PT6301 and attains low power consumption of VDD and VDISP.
Note: If the RESET signal is input while the stand-by mode in progress, the stand-by mode is released and all states are
initialized.
COMMAND FORMAT
MSB
LSB
1st Byte
(1st)
B7 B6 B5 B4 B3 B2 B1 B0 Selects the stand-by mode
111
1
*
*
*
*
*: Don’t care.
RELEASING THE STAND-BY MODE
The timing to release the stand-by mode is shown below.
The stand-by mode is released at the falling edge of CS. (The internal oscillation starts)
When the oscillation becomes stable, the data input is enabled. (Return CS to “High” before entering data)
After the stand-by mode is released, all display-lights are turned off. Release the all display-lights OFF mode to turn on
the display-lights.
Da ta inpu t
CS
CP
Sta nd-by sta te
(O s ci lla tion s top)
OSC
m or e th an 20 0ns
m or e th an 20 0ns
B0 B1 B2 B3 B4 B5 B6 B7
LSB
First byte
No rm all y op er atio n ( A ll ou tput ar e "Low ")
M SB
Oscillation state
Oscillation starts
V1.2
15