Electrical and Thermal Characteristics
Table 6. Clock AC Timing Specifications
Num
Characteristic
SYSCLK/Core
33/66 MHz
Min
Max
SYSCLK/Core
33/83.3 MHz
Min
Max
Unit Notes
— 60x processor bus (core) frequency
16.67
66
16.67
83.3
MHz
1
— VCO frequency
120
200
120
200
MHz 1, 2
— SYSCLK frequency
16.67
33.33
16.67
33.33 MHz
1
1 SYSCLK cycle time
30.0
60.0
30.0
60.0
ns
2, 3 SYSCLK rise and fall time
2.0
2.0
ns
3
4 SYSCLK duty cycle measured at 1.4 V
40
60
40
60
%
4
— SYSCLK jitter
±200
±200
ps
5
— 106 internal PLL relock time
100
100
µs
4, 6
Notes:
1 Caution: The SYSCLK frequency and PLL[0–3] settings must be chosen such that the resulting SYSCLK (bus)
frequency, CPU (core) frequency, and PLL (VCO) frequency do not exceed their respective maximum or minimum
operating frequencies. Refer to the PLL[0–3] signal description in Section 1.8, “System Design Information,” for
valid PLL[0–3] settings, and to Section 1.9, “Document Revision History,” for available frequencies and part
numbers.
2 VCO operating range for extended temperature devices is different. Refer to MPC106ARXTGPNS/D for more
information.
3 Rise and fall times for the SYSCLK input are measured from 0.4 V to 2.4 V.
4 Timing is guaranteed by design and characterization and is not tested.
5 The total input jitter (short-term and long-term combined) must be under ±200 ps.
6 PLL-relock time is the maximum time required for PLL lock after a stable Vdd, AVdd, and SYSCLK are reached
during the power-on reset sequence. This specification also applies when the PLL has been disabled and
subsequently re-enabled during the sleep and suspend power-saving modes. Also note that HRST must be held
asserted for a minimum of 255 bus clocks after the PLL-relock time (100 µs) during the power-on reset sequence.
Figure 2 provides the SYSCLK input timing diagram.
1
2
3
4
4
CVIH
SYSCLK
VM
VM
VM
CVIL
VM = Midpoint Voltage (1.4 V)
Figure 2. SYSCLK Input Timing Diagram
1.4.2.2 Input AC Specifications
Table 7 provides the input AC timing specifications for the 106 as defined in Figure 3 and Figure 4. These
specifications are for operation between 16.67 and 33.33 MHz PCI bus clock (SYSCLK) frequencies.
Assume Vdd = AVdd = 3.3 ± 5% V DC, GND = 0 V DC, and 0 Tj 105 °C.
8
MPC106 PCI Bridge/Memory Controller Hardware Specifications