[Elite Semiconductor Memory Technology Inc.
GENERAL DESCRIPTION
NAND Flash devices include an asynchronous data interface for high-performance I/O operations. These devices use a highly multiplexed 8-bit bus (I/Ox) to transfer commands, address, and data. There are five control signals used to implement the asynchronous data interface: CE#, CLE, ALE, WE#, and RE#. Additional signals control hardware write protection and monitor device status (R/B#).
This hardware interface creates a low pin-count device with a standard pinout that remains the same from one density to another, enabling future upgrades to higher densities with no board redesign.
FEATURES
◾ Voltage Supply: 1.8V (1.7 V ~ 1.95V)
◾ Open NAND Flash Interface (ONFI) 1.0-compliant
◾ Single-level cell (SLC) technology
◾ Organization
– Page size: 4352 bytes (4096 + 256 bytes)
– Block size: 64 pages
– Number of planes: 1
– Device size: 4Gb
◾ Asynchronous I/O performance
– tRC/ tWC: 30ns
◾ Array performance
– Read page: 115μs (MAX) with on-die ECC enabled
– Read page: 30μs (MAX) with on-die ECC disabled
– Program page: 200μs (TYP) with on-die ECC
disabled
– Program page: 240μs (TYP) with on-die ECC
enabled
– Erase block: 2ms (TYP)
◾ Command set: ONFI NAND Flash Protocol
◾ Advanced command set
– Program page cache mode
– Read page cache mode
– Permanent block locking (blocks 47:0)
– One-time programmable (OTP) mode
– Block lock
– Programmable drive strength
– Read unique ID
– Internal data move
◾ Operation status byte provides software method for
detecting
– Operation completion
– Pass/ fail condition
– Write-protect status
◾ Ready/ Busy# (R/B#) provides a hardware method of
detecting operation completion
◾ WP# signal: Write protect entire device
◾ ECC: 8-bit internal ECC is disabled at default (it can be
toggled using the SET FEATURE command)
◾ Block 0 is valid when shipped from factory with ECC; for
minimum required ECC, see Error Management.
◾ RESET (FFh) required as first command after power-on
◾ Alternate method of automatic device initialization after
power-up (contact factory)
◾ Internal data move operations supported within the
plane from which data is read
◾ Quality and reliability
– Endurance: 100,000 PROGRAM/ERASE cycles
– Data retention: JESD47G-compliant
– Additional: Uncycled data retention: 10 years 24/7
@ 70°C