LTC7000/LTC7000-1
APPLICATIONS INFORMATION
Cooldown Period and Restart
As soon as TIMER reaches 1.4V, TGDN is pulled to TS in an
overcurrent fault condition and the TIMER pin starts dis-
charging with a 2.5µA current. When TIMER reaches 0.4V,
TIMER charges with a 2.5µA current. When TIMER reaches
1.4V, it starts discharging again with a 2.5µA current. This
pattern repeats 32 times to form a long cooldown timer
period (TCOOL_DOWN) before retry (Figure 5).
If INP is cycled low, TGDN will be pulled to TS and TIMER
will be pulled low with an internal 100kΩ resistor. If INP is
cycled low during the cooldown period, the timer counter
will be reset. If INP then goes high, TGUP will pulled to
BST and the fault timer will be reactivated with the TIMER
voltage starting from it’s current value.
At the end of the cooldown period (when TIMER drops
below 0.4V for the 32nd time), the LTC7000/LTC7000-1
retries, pulling TGUP to BST and turning on the external
MOSFET. The FAULT pin will then go to a high impedance
state. The total cooldown timer period is given by:
TCOOL
_ DOWN
=
63
1.0V • CTIMER
2.5µA
The retry duty cycle in percent is to a first order indepen-
dent of CT and is defined by:
D=
100 • TOVER _ CURRENT
TOVER _ CURRENT + TCOOL _ DOWN
To defeat the automatic retry, place a 100kΩ resistor in
parallel with the TIMER capacitor. Note that the time to
turn off from an overcurrent fault will be increased by 7%
and the FAULT pin will remain low indicating a fault has
occurred. To get the LTC7000/LTC7000-1 to retry and to
clear the fault flag the INP signal needs to cycle low then
back high.
Typical turn-off times and cooldown periods for some
standard value timer capacitors are shown Table 1:
Table 1. Fault Time for Typical Capacitors
CTIMER
(nF)
TOVER_CURRENT
(µs)
TCOOL_DOWN
(s)
<0.1
~3
0.0005
1
16
0.025
10
142
0.250
100
1402
2.500
Retry Duty Cycle
%
~0.6
0.06
0.06
0.06
∆VSNS
>30mV
1.40V
1.30V
TIMER
FAULT
0.4V
1ST
<30mV
2ND
31ST
32ND
V(TG-TS)
(TGUP SHORTED TO TGDN)
INP
7000 F05
COOLDOWN PERIOD (TCOOL_DOWN)
Figure 5. Auto Retry Cool-Down Timer Cycle
For more information www.analog.com