AC Electrical Characteristics
Symbol
Parameter
VCC
TA = 25°C
TA =−40°C to +85°C
Units
(V)
Min
Typ
Max
Min
Max
Conditions
tPLH
Propagation Delay
tPHL
In to Zn
tPLH
Propagation Delay
tPHL
Sn to Zn
tPLH
Propagation Delay
tPHL
En to Zn
CIN
Input Capacitance
CPD
Power Dissipation
Capacitance
3.3 ± 0.3
5.0 ± 0.5
3.3 ± 0.3
5.0 ± 0.5
3.3 ± 0.3
5.0 ± 0.5
7.7
11.9
1.0
14.0
ns CL = 15 pF
10.2
15.4
1.0
17.5
CL = 50 pF
5.0
7.7
1.0
9.0
ns CL = 15 pF
6.5
9.7
1.0
11.0
CL = 50 pF
10.8
16.7
1.0
19.5
ns CL = 15 pF
13.3
20.2
1.0
23.0
CL = 50 pF
6.8
9.9
1.0
11.5
ns CL = 15 pF
8.3
11.9
1.0
13.5
CL = 50 pF
6.3
10.1
1.0
12.0
ns CL = 15 pF
8.8
13.6
1.0
15.5
CL = 50 pF
4.4
6.4
1.0
7.5
ns CL = 15 pF
5.9
8.4
1.0
9.5
CL = 50 pF
4
10
10
pF VCC = Open
20
pF (Note 3)
Note 3: CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load. Average
operating current can be obtained by the equation: ICC (opr.) = CPD * VCC * fIN + ICC.
www.fairchildsemi.com