ST3237EB
Electrical characteristics
Table 8.
Symbol
Receiver (C1 - C4 = 0.1 µF tested at 3.3 V ±10 %, VCC = 3 V to 5.5 V, TA = -40 to 85 °C,
unless otherwise specified. Typical values are referred to TA = 25°C)
Parameter
Test conditions
Min.
Typ. Max. Unit
IOL
VOL
VOH
VRIN
Output leakage current
Output voltage low
Output voltage high
Receiver input voltage
operating range
Receiver disabled, EN = VCC
IOUT = 1mA
IOUT = -1mA
± 0.05 ± 10 µA
0.4
V
VCC-0.6 VCC-0.1
V
-25
25
V
VRIL
RS-232 input threshold
low
VRIH
RS-232 input threshold
high
VRIHYS
RRIN
Input hysteresis
Input resistance
TA = 25°C, VCC = 3.3V
TA = 25°C, VCC = 5V
TA = 25°C, VCC = 3.3V
TA = 25°C, VCC = 5V
TA = 25°C
0.6
1.1
V
0.8
1.5
1.5
2.4
V
1.2
2.4
0.3
V
3
5
7
KΩ
Table 9.
Symbol
Timing characteristics (C1 - C4 = 0.1 µF tested at 3.3 V ±10 %, VCC = 3 V to 5.5 V,
TA = -40 to 85 °C, unless otherwise specified. Typical values are referred to TA = 25 °C)
Parameter
Test conditions
Min. Typ. Max. Unit
RL = 3KΩ, CL= 1000pF
one transmitter switching, VHSCI=GND
DR
tPHLR
tPLHR
tPHLR
tPLHR
Maximum data rate
Propagation delay input to
output
Propagation delay input to
output
RL = 3KΩ, CL= 250pF
one transmitter switching, VHSCI=VCC
VCC= 3 to 4.5V
RL = 3KΩ, CL= 1000pF
one transmitter switching, VHSCI=VCC
VCC= 4.5 to 5.5V
RIN to ROUT, CL = 150pF
RL = 3kΩ, CL = 1000pF,
VHSCI=VCC
VHSCI=GND
tT_SKEW Transmitter skew
|tPHL - tTLH|, VHSCI=GND
|tPHL - tTLH|, VHSCI=VCC
tR_SKEW Receiver skew
|tPHL - tTLH|
tOER Receiver output enable time Normal operation
tODR Receiver output disable time Normal operation
SRT Transition slew rate
TA = 25°C RL = 3 to 7KΩ, VCC = 3.3V
measured from +3V to -3V or -3V to +3V
CL = 150pF to 1000pF, VHSCI=GND
CL = 150pF to 1000pF, VHSCI=VCC
CL = 150pF to 2500pF, VHSCI=GND
250
1000
Kbps
Kbps
1000
0.15
400
1000
300
50
100
50
120
Kbps
µs
ns
ns
ns
ns
ns
ns
ns
6
30 V/µs
24
150 V/µs
4
30 V/µs
Note:
Transmitter skew is measured at the transmitter zero cross points
7/18