M41T81
5
DC and AC parameters
DC and AC parameters
Note:
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 7. Operating and AC measurement conditions
Parameter
Supply voltage (VCC)
Ambient operating temperature (TA)
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
M41T81
2.0 to 5.5 V
–40 to 85°C
100 pF
≤ 50 ns
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Output Hi-Z is defined as the point where data is no longer driven.
Figure 14. AC measurement I/O waveform
0.8VCC
0.2VCC
0.7VCC
0.3VCC
AI02568
Table 8. Capacitance
Symbol
Parameter(1)(2)
Min
CIN
Input capacitance
-
COUT(3)
Output capacitance
-
tLP
Low-pass filter input time constant (SDA and SCL)
-
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
3. Outputs deselected.
Max
7
10
50
Unit
pF
pF
ns
Doc ID 7529 Rev 10
21/29