Nexperia
74AHC123A-Q100; 74AHCT123A-Q100
Dual retriggerable monostable multivibrator with reset
Table 7. Dynamic characteristics …continued
GND = 0 V; For test circuit see Figure 12.
Symbol Parameter Conditions
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ[1] Max Min
Max
Min
Max
trtrig
retrigger
nA to nB; Cext = 100 pF;
time
Rext = 1 k; CL = 50 pF;
see Figure 8 and Figure 10
VCC = 4.5 V to 5.5 V
- 60 -
-
-
-
-
ns
nA to nB; Cext = 0.01 F;
Rext = 1 k; CL = 50 pF;
see Figure 8 and Figure 10
VCC = 4.5 V to 5.5 V
- 1.5 -
-
-
-
-
s
CPD
power
CL = 50 pF; fi = 1 MHz;
[4] -
58 -
-
-
-
-
pF
dissipation VI = GND to VCC
capacitance
External components
Rext
external
VCC = 2.0 V
resistance VCC > 3.0 V
Cext
external
VCC = 2.0 V
capacitance VCC > 3.0 V
5
-
-
-
-
-
-
k
1
-
-
-
-
-
-
k
[5] -
-
-
-
-
-
-
pF
[5] -
-
-
-
-
-
-
pF
[1] Typical values are measured at nominal supply voltage (VCC = 3.3 V and VCC = 5.0 V).
[2] tpd is the same as tPLH and tPHL; Cext = 0 pF; Rext = 5 k.
[3] For Cext 10 nF, the typical value of the pulse width tW (s) = Cext (nF) Rext (k).
[4] CPD is used to determine the dynamic power dissipation PD (W).
PD = CPD VCC2 fi + (CL VCC2 fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V.
[5] Cext has no limits.
74AHC_AHCT123A_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 23 May 2013
© Nexperia B.V. 2017. All rights reserved
12 of 22