W83877F
2.1.7 FDC Commands
Command Symbol Descriptions:
C:
Cylinder number 0 - 256
D:
DIR:
Data Pattern
Step Direction
DIR = 0, step out
DIR = 1, step in
DS0:
DS1:
Disk Drive Select 0
Disk Drive Select 1
DTL:
EC:
Data Length
Enable Count
EOT:
EFIFO:
End of Track
Enable FIFO
EIS:
EOT:
Enable Implied Seek
End of track
FIFOTHR: FIFO Threshold
GAP:
Gap length selection
GPL:
H:
Gap Length
Head number
HDS:
HLT:
HUT:
Head number select
Head Load Time
Head Unload Time
LOCK:
MFM:
Lock EFIFO, FIFOTHR, PTRTRK bits prevent affected by software reset
MFM or FM Mode
MT:
Multitrack
N:
The number of data bytes written in a sector
NCN:
ND:
New Cylinder Number
Non-DMA Mode
OW:
PCN:
Overwritten
Present Cylinder Number
POLL:
Polling Disable
PRETRK: Precompensation Start Track Number
R:
RCN:
Record
Relative Cylinder Number
R/W:
SC:
Read/Write
Sector/per cylinder
SK:
Skip deleted data address mark
- 21 -