Corcom Product Guide
AC Feedthrough Filters – Class Y2
FFA Series
Component Recognized by
UL to US and Canadian Requirements
Catalog: 1654001
Issue Date: 06.2011
FFA Series
Specifications
• AC feedthrough filters
• Current Ratings from 10 to 300A
• Designed to meet the very stringent safety
requirements of EN133200 class Y2 including
the 5000V pulse test
Rated Voltage (max):
Operating Frequency:
Rated Current:
Test Voltage (two seconds):
Capacitor Class (EN133200):
250 VAC
50/60 Hz
10 to 300A
5000 VDC
Designed to meet Y2
• Custom versions available
Ordering Information
10 FFA6 – BA
Filter ID
See Table
FFA Series Screw Terminals
Current Rating (in A)
Filter Options / Specifications
Filter
ID
BA
CA
CE
DG
DH
GB
GJ
HC
HD
HF
HN
JK
NP
PP
Value (nF)
2 x 4.7
2 x 10
2 x 10
2 x 22
2 x 22
2 x 47
2 x 47
2 x 100
2 x 100
2 x 100
2 x 100
2 x 150
2 x 470
2 x 1000
Max.
Leakage DC
Inductance Current Resistance
(nH)
(mA)* (m) Max.
70
0.9
6
70
1.9
4
140
1.9
7
170
4.2
4
180
4.2
4
80
8.9
3
210
8.9
9
90
19
2
120
19
1
160
19
<1
250
19
6
240
29
3
330**
89
<2
330
188
<2
Pulse Test (EN133200):
5000V Peak
Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M
For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range
(at rated current Ir):
10 to 100A: -40°C to +60°C
200A: -40°C to +50°C
250 & 300A: -40°C to +40°C
Category Temperature Range:
-40°C to +85°C
Current Derating Above Ambient:
10-100A: For temperature, = R (85-)/25
200A: For temperature, = R (85-)/35
250 & 300A: For temp., = R (85-)/45
Climatic Category:
40/85/21
MTBF:
> 5 million hours typical
Insulating Materials Flammability Rating: UL94V-0
Case & Terminal Material:
Nickel Plated Brass
Electrical Schematic
228
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help