POWER REQUIRE E TS (Note 5)
SYMBOL
VDD
VSS
IDD
ISS
PD
PARAMETER
Positive Supply Voltage
Negative Supply Voltage
Positive Supply Current
Nap Mode
Sleep Mode
Negative Supply Current
Nap Mode
Sleep Mode
Power Dissipation
Nap Mode
Sleep Mode
CONDITIONS
(Notes 12, 13)
(Note 12)
CS = RD = 0V
CS = 0V, SHDN = 0V
CS = 5V, SHDN = 0V
CS = RD = 0V
CS = 0V, SHDN = 0V
CS = 5V, SHDN = 0V
CS = RD = 0V
CS = 0V, SHDN = 0V
CS = 5V, SHDN = 0V
WU
TI I G CHARACTERISTICS (Note 5)
SYMBOL
fSMPL(MAX)
tCONV
tACQ
tACQ+CONV
t1
t2
t3
t4
t5
t6
PARAMETER
Maximum Sampling Frequency
Conversion Time
Acquisition Time
Throughput Time (Acquisition + Conversion)
CS to RD Setup Time
CS↓ to CONVST↓ Setup Time
SHDN↓ to CS↑ Setup Time
SHDN↑ to CONVST↓ Wake-Up Time
CONVST Low Time
CONVST to BUSY Delay
CONDITIONS
(Note 11)
(Notes 11, 12)
(Notes 11, 12)
(Notes 11, 12)
CS = Low (Note 12)
(Note 12)
CL = 25pF
t7
Data Ready Before BUSY↑
t8
Delay Between Conversions
t9
Wait Time RD↓ After BUSY↑
t10
Data Access Time After RD↓
(Note 12)
(Note 12)
CL = 25pF
CL = 100pF
t11
Bus Relinquish Time
LTC1604C
LTC1604I
t12
RD Low Time
(Note 12)
t13
CONVST High Time
(Note 12)
t14
Aperture Delay of Sample-and-Hold
MIN TYP MAX
4.75
5.25
– 4.75
– 5.25
q
18
30
1.5
2.4
1
100
q
26
40
1
100
1
100
q
220 350
7.5
12
0.01
1
UNITS
V
V
mA
mA
µA
mA
µA
µA
mW
mW
mW
MIN TYP MAX
q 333
q 1.5
2.45
2.8
q
480
q
3
q
0
q 10
q 10
400
q 40
36
q
80
60
q 32
q 200
q –5
40
50
q
60
45
60
q
75
50
60
q
70
q
75
q
t10
q 40
2
UNITS
kHz
µs
ns
µs
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
4