SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE
MODEL NO: 16244
4. RELIABILITY
No Test Item
.
1 High temperature
storage
2 Low temperature
storage
3 High temperature
operation
4 Low temperature
operation
5 High temperature /
Humidity storage
6 High temperature /
Humidity operation
7 Temperature cycle
Environmental Test
Content of Test
Test Condition
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to
the element for a long time.
Endurance test applying the electric stress
under low temperature for a long time.
Endurance test applying the high temperature
and high humidity storage for a long time.
Endurance test applying the electric stress
(Voltage & Current) and temperature / humidity
stress to the element for a long time.
Endurance test applying the low and high
temperature cycle.
-20°C
25°C
70°C
30min.
5min.
30min.
80 °C
200 hrs
-30 °C
200 hrs
70 °C
200 hrs
-20 °C
200 hrs
80 °C , 90 %RH
96 hrs
70 °C , 90 %RH
96 hrs
-20°C / 70°C
10 cycles
Applicable
Standard
------
------
------
------
MIL-202E-103B
JIS-C5023
MIL-202E-103B
JIS-C5023
------
1
Mechanical Test
8 Vibration test
Endurance test applying the vibration during
transportation and using.
1022Hz 1.5mmp-p
22500Hz 1.5G
Total 0.5hrs
9 Shock test
Constructional and mechanical endurance test 50G Half sign
applying the shock during transportation.
wave 1l msedc
3 times of each direction
10 Atmospheric
Endurance test applying the atmospheric
115 mbar
pressure test
pressure during transportation by air.
40 hrs
Others
11 Static electricity test Endurance test applying the electric stress to the VS=800V , RS=1.5 kΩ
terminal.
CS=100 pF
1 time
∗∗∗ Supply voltage for logic system = VDD. Supply voltage for LCD system = Operating voltage at 25°C
MIL-202E-201A
JIS-C5025
JIS-C7022-A-10
MIL-202E-213B
MIL-202E-105C
MIL-883B-
3015.1
LCD Panel Service Life
Definition of panel service life
100,000 hours minimum at 25° C ±10%
Contrast becomes 30% of initial value
Current consumption becomes three times higher than initial value
Remarkable alignment deterioration occurs in LCD cell layer
Unusual operation occurs in display functions
PACIFIC DISPLAY DEVICES