datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

S-24C16CH-XXXXU3 查看數據表(PDF) - Seiko Instruments Inc

零件编号
产品描述 (功能)
生产厂家
S-24C16CH-XXXXU3
SII
Seiko Instruments Inc 
S-24C16CH-XXXXU3 Datasheet PDF : 35 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Rev.2.2_01_H
FOR AUTOMOTIVE 105°C OPERATION 2-WIRE SERIAL E2PROM
S-24C16C H Series
Initial Delivery State
Initial delivery state of all addresses is "FFh".
Operation
1. Start condition
Start is identified by a high to low transition of the SDA line while the SCL line is stable at high.
Every operation begins from a start condition.
2. Stop condition
Stop is identified by a low to high transition of the SDA line while the SCL line is stable at high.
When a device receives a stop condition during a read sequence, the read operation is interrupted, and the device
enters standby mode.
When a device receives a stop condition during a write sequence, the reception of the write data is halted, and the
S-24C16C initiates a write cycle.
tSU.STA tHD.STA
tSU.STO
SCL
SDA
Start Condition
Figure 8 Start / Stop Conditions
Stop Condition
9