datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

X9319UPI(2006) 查看數據表(PDF) - Intersil

零件编号
产品描述 (功能)
生产厂家
X9319UPI Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
X9319
A.C. OPERATING CHARACTERISTICS
(VCC = 5V ±10%, TA = Full Operating Temperature Range unless otherwise stated)
Limits
Symbol
Parameter
Min.
Typ.(4)
tCl
tlD(5)
tDI(5)
tlL
tlH
tlC
tCPHS
tCPHNS(5)
tIW(5)
tCYC
tR, tF(5)
tPU(5)
tR VCC(5)
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
CS deselect time (NO STORE)
INC to RW change
INC cycle time
INC input rise and fall time
Power-up to wiper stable
VCC power-up rate
100
100
1
1
1
1
20
1
100
4
0.2
Max.
500
500
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
µs
V/ms
POWER-UP AND DOWN REQUIREMENTS
In order to prevent unwanted tap position changes, or an inadvertant store, bring the CS and INC high before or con-
currently with the VCC pin on powerup. The potentiometer voltages must be applied after this sequence is completed.
During power-up, the data sheet parameters for the DCP do not fully apply until 1 millisecond after VCC reaches its
final value. The VCC ramp spec is always in effect.
A.C. TIMING
CS
tCI
INC
U/D
tIW
RW
tCYC
tIL
tIH
tID
tIC
tDI
MI (3)
tCPHS
90% 90%
10%
tCPHNS
tF
tR
5
FN8185.2
September 26, 2006

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]