www.vishay.com
VO617A
Vishay Semiconductors
IF IF
0
+5V
R G = 50 Ω
tp
= 0.01
T
tp = 50 µs
50 Ω
Channel I
Channel II
RL
Oscilloscope
R L = 1 MΩ
C L = 20 pF
95 10804 3
Fig. 2 - Test Circuit, Non-Saturated Operation
IF IF = 10 mA
0
+5V
IC
IF
0
tp
IC
t
100 %
90 %
10 %
0
tp
td
tr
ton (= td + tr)
tr
td
t on
Pulse duration
Delay time
Rise time
Turn-on time
ts
tf
t off
ts
tf
toff (= ts + tf)
Fig. 4 - Switching Times
t
Storage time
Fall time
Turn-off time
96 11698
RG = 50 Ω
tp
= 0.01
T
t p = 50 µs
50 Ω
1 kΩ
Channel I
Channel II
Oscilloscope
RL ≥ 1 MΩ
CL ≤ 20 pF
95 10843
Fig. 3 - Test Circuit, Saturated Operation
SAFETY AND INSULATION RATINGS
PARAMETER
SYMBOL
VALUE
UNIT
MAXIMUM SAFETY RATINGS
Output safety power
Input safety current
Safety temperature
Comparative tracking index
INSULATION RATED PARAMETERS
Maximum withstanding isolation voltage
Maximum transient isolation voltage
Maximum repetitive peak isolation voltage
Insulation resistance
Tamb = 25 °C, VDC = 500 V
Isolation resistance
Tamb = 100 °C, VDC = 500 V
Climatic classification (according to IEC 68 part 1)
Environment (pollution degree in accordance to DIN VDE 0109)
DIP-4
Internal and external creepage
SMD-4 (option 7)
DIP-4, 400 mil (option 6)
SMD-4, 400 mil (option 8)
DIP-4
Clearance
SMD-4 (option 7)
DIP-4, 400 mil (option 6)
SMD-4, 400 mil (option 8)
Insulation thickness
PSO
Isi
TS
CTI
VISO
VIOTM
VIORM
RIO
RIO
DTI
265
130
150
175
5300
8000
890
≥ 1012
≥ 1011
55/110/21
2
≥7
≥7
≥8
≥8
≥7
≥7
≥8
≥8
0.4
mW
mA
°C
VRMS
Vpeak
Vpeak
Ω
Ω
mm
mm
mm
mm
mm
mm
mm
mm
mm
Note
• As per DIN EN 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance
with the safety ratings shall be ensured by means of protective circuits.
Rev. 2.3, 28-Oct-14
4
Document Number: 83430
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000