VC-23 Series
s REFLOW MOUNTING CONDITIONS (RECOMMENDED)
• Perform mounting using the temperature profile shown below. To prevent thermal stress to the VCO, ensure
gentle temperature gradients and use preheating whenever possible. (Recommended preheating: 140°C to
160°C for 60 s ± 20 s)
• Always consult FUJITSU MEDIA DEVICE beforehand if mounting more than once.
• Never remove a VCO that has already been mounted and attempt to reuse.
• For mounting, use a general-purpose flux suitable for mounting electronic components.
250
230 ± 10
200
160
150
140
100
∗1
60 s ± 20 s
7 s Max.
∗2
20 s ∼ 30 s
50
Warm-up
0
Pre-heating
Heating
Time (s)
Cooling
∗1 : 10°C/s or less
∗2 : 8 °C/s or less
s WASHING CONDITIONS
• Washing solution: Use isopropyl alcohol.
• Washing procedure: Immersion or steam cleaning is recommended.
• Washing time: For immersion: Less than 5 minutes at 40°C or less.
For steam: Less than 2 minutes at 90°C or less is recommended.
10