datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

TOP412 查看數據表(PDF) - Power Integrations, Inc

零件编号
产品描述 (功能)
生产厂家
TOP412
Power-Integrations
Power Integrations, Inc 
TOP412 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TOP412/414
TOPSwitch Family Functional Description
TOPSwitch is a self biased and protected linear control current-
to-duty cycle converter with an open drain output. High
efficiency is achieved through the use of CMOS and integration
of the maximum number of functions possible. CMOS
significantly reduces bias currents as compared to bipolar or
discrete solutions. Integration eliminates external power resistors
used for current sensing and/or supplying initial start-up bias
current.
Auto-restart
IB
DMAX
Slope = PWM Gain
-16%/mA
During normal operation, the internal output MOSFET duty
cycle linearly decreases with increasing CONTROL pin current
as shown in Figure 4. To implement all the required control,
bias, and protection functions, the DRAIN and CONTROL pins
each perform several functions as described below. Refer to
Figure 2 for a block diagram and Figure 6 for timing and voltage
waveforms of the TOPSwitch integrated circuit.
Control Voltage Supply
CONTROL pin voltage VC is the supply or bias voltage for the
controller and driver circuitry. An external bypass capacitor
closely connected between the CONTROL and SOURCE pins
is required to supply the gate drive current. The total amount of
capacitance connected to this pin (CT) also sets the auto-restart
timing as well as control loop compensation. VC is regulated in
either of two modes of operation. Hysteretic regulation is used
for initial start-up and overload operation. Shunt regulation is
used to separate the duty cycle error signal from the control
circuit supply current. During start-up, VC current is supplied
from a high-voltage switched current source connected internally
between the DRAIN and CONTROL pins. The current source
provides sufficient current to supply the control circuitry as
well as charge the total external capacitance (CT).
DMIN
ICD1 2.5
6.5
IC (mA)
45
PI-1691-112895
Figure 4. Relationship of Duty Cycle to CONTROL Pin Current.
5.7 V
4.7 V
VC
0
IC
Charging CT
DRAIN VIN
Off
0
5.7 V
VC 4.7 V
0
IC
Charging CT
Switching
(a)
ICD1
Discharging CT
ICD2
Discharging CT
8 Cycles
95%
5%
DRAIN VIN
0
Off
Off
Off
Switching
(b)
Switching
CT is the total external capacitance
connected to the CONTROL pin
PI-1124A-060694
Figure 5. Start-up Waveforms for (a) Normal Operation and (b)
Auto-restart.
3 A
4/99

Share Link: 