SY NERGY
SEMICONDUCTOR
ClockWorks™
SY10H641A
SY100H641A
10H ECL DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Max. Min. Max. Min. Max. Unit
IIH
Input HIGH Current
—
225
—
175
—
175
µA
IIL
Input LOW Current
VIH
Input HIGH Voltage(1)
0.5
—
0.5
—
0.5
—
µA
3.830 4.160 3.870 4.190 3.940 4.280
V
VIL
Input LOW Voltage(1)
3.050 3.520 3.050 3.520 3.050 3.555
V
VBB
Output Reference Voltage(1)
3.620 3.730 3.650 3.750 3.690 3.810
V
NOTE:
1. VIH, VIL and VBB are referenced to VE and will vary 1:1 with the power supply. The levels shown are for VE = +5.0V.
Condition
—
—
VE = 5.0V
VE = 5.0V
VE = 5.0V
100H ECL DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Max.
Min. Max. Min. Max. Unit
IIH
Input HIGH Current
—
225
—
175
—
175
µA
IIL
Input LOW Current
0.5
—
0.5
—
0.5
—
µA
VIH
Input HIGH Voltage(1)
3.835 4.120 3.835 4.120 3.835 4.120
V
VIL
Input LOW Voltage(1)
3.190 3.525 3.190 3.525 3.190 3.525
V
VBB
Output Reference Voltage(1)
3.620 3.740 3.620 3.740 3.620 3.740
V
NOTE:
1. VIH, VIL and VBB are referenced to VE and will vary 1:1 with the power supply. The levels shown are for VE = +5.0V.
Condition
—
—
VE = 5.0V
VE = 5.0V
VE = 5.0V
AC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Max. Min. Max. Min. Max. Unit
Condition
tPLH
tPHL
tskpp
tskew++
tskew– –
Propagation Delay
D to Output
Part-to-Part Skew(1,4)
Within-Device Skew(2,4)
Within-Device Skew(3,4)
5.0
6.0
5.0 6.0
5.0
6.0
ns
—
0.5
— 0.5
—
0.5
ns
—
0.3
— 0.3
—
0.3
ns
—
0.3
— 0.3
—
0.3
ns
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
tPLH
Propagation Delay
tPHL
LEN to Output
4.9
6.9
4.9 6.9
5.0
7.0
ns
CL = 50pF
tPLH
Propagation Delay
tPHL
EN to Output
5.0
7.0
4.9 6.9
5.0
7.0
ns
CL = 50pF
tr
tf
fMAX
Output Rise/Fall Time
0.8V to 2.0V
Maximum Input Frequency(5,6)
—
1.7
— 1.7
—
1.7
ns
—
1.6
— 1.6
—
1.6
80
—
80
—
80
— MHz
CL = 50pF
CL = 50pF
—
Pulse Width
1.5
—
1.5 —
1.5
—
ns
—
—
Recovery Time
1.25 — 1.25 — 1.25 —
ns
—
tS
Set-up Time
0.5 (typ.)
0.5 (typ.)
0.5 (typ.)
ns
—
tH
Hold Time
0.5 (typ.)
0.5 (typ.)
0.5 (typ.)
ns
—
NOTES:
1. Device-to-Device Skew considering HIGH-to-HIGH transitions at common
power supply voltage.
2. Within-Device Skew considering HIGH-to-HIGH transitions at common
power supply voltage.
3. Within-Device Skew considering LOW-to-LOW transitions at common
power supply voltage.
4. All skew parameters are guaranteed but not tested.
5. Frequency at which output levels will meet a 0.8V to 2.0V minimum swing.
6. The fMAX value is specified as the minimum guaranteed maximum
frequency. Actual operational maximum frequency may be greater.
5-358