Photo Link Module
RPM6900 series
(2) Standard transmitter
λ peak=940nm
λ ∆=40nm
Lo=20cm
Signal scale
io=5µAp-p
i
Carrier frequency fo
Brachy morphic wave duty50%
io
Standard transmitter
A
io
ON
OFF
10kΩ
t
Standard photo-diode
RPM-301B
600µs 600µs
Fig.2 Measurement of standard transmitter proofreading
Fig.3 Standard photo diode current
When standard transmitter output the signal at Fig.1 standard photodiode output become io=5µAp-p (Fig.3) under the
measurement condition Fig.2.
(The radiant intensity of standard transmitter : 50mW / sr)
RPM-301B : standard photodiode has short current Isc=27µA at E=1000(lx)
(using CIE standard light source A)
(3) Measurement effective distance, horizontal & vertical half angle
Standard transmitter
RPM6900 series
θ
θ
Light detector face
illuminance : Ee
Effective distance : L
(θ ; Indicates horizontal and vertical directions)
Fig.4 Measurement condition for effective distance
Effective distance L
: Effective distance at θ=0° Fig.4
Horizontal & vertical half angle θ : The angle which effective distance became 50% of L.
3/7