Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
PS21265-P / PS21265-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
Inductive Load Switching Times
ICES
VEC
VCE(sat)
ton
trr
tC(on)
toff
tC(off)
VCE = VCES, Tj = 25°C
VCE = VCES, Tj = 125°C
Tj = 25°C, -IC = 20A, VIN = 0V
IC = 20A, Tj = 25°C, VD = VDB = 15V, VIN = 5V
IC = 20A, Tj = 125°C, VD = VDB = 15V, VIN = 5V
VCC = 300V, VD = VDB = 15V,
IC = 20A, Tj = 125°C, VIN = 5 ⇔ 0V,
Inductive Load (Upper-Lower Arm)
—
—
—
—
—
0.65
—
—
—
—
—
—
1.5
1.55
1.65
1.25
0.30
0.40
1.50
0.50
1.0
10
2.0
2.05
2.15
1.85
—
0.60
2.10
0.80
mA
mA
Volts
Volts
Volts
µs
µs
µs
µs
µs
TC Measurement Point
T
CONTROL TERMINALS
HEATSINK BOUNDARY
TC
POWER TERMINALS TC
08/10 Rev. 01
3