[2] CPD is used to determine the dynamic power dissipation (PD in µW).
PD = CPD × VCC2 × fi × N + Σ(CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
Σ(CL × VCC2 × fo) = sum of the outputs.
[3] The condition is VI = GND to VCC.
12. Waveforms
74LV164
8-bit serial-in/parallel-out shift register
VI
CP input
GND
VOH
Qn output
VOL
1/ fmax
VM
tW
t PHL
VM
t PLH
001aac426
Fig 6.
Measurement points are given in Table 9.
VOL and VOH are typical output voltage drop that occur with the output load.
Propagation delay clock (CP) to output (Qn), clock pulse width and maximum clock
frequency
VI
MR input
GND
VI
CP input
GND
VOH
Qn output
VOL
VM
tW
t rem
t PHL
VM
VM
001aac427
Fig 7.
Measurement points are given in Table 9.
VOL and VOH are typical output voltage drop that occur with the output load.
Pulse width master reset (MR), propagation delay master reset (MR) to output (Qn)
and removal time master reset (MR) to clock (CP)
9397 750 14501
Product data sheet
Rev. 03 — 4 February 2005
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.