M27V800
Table 8. Read Mode AC Characteristics (1)
(TA = 0 to 70 °C; VCC = 3.3V ± 10%; VPP = VCC)
M27V800
Symbol Alt
Parameter
Test Condition
-100
-120
-150
Unit
Min Max Min Max Min Max
tAVQV
tACC
Address Valid to
Output Valid
E = VIL, G = VIL
100
120
150 ns
tBHQV
tST
BYTE High to Output
Valid
E = VIL, G = VIL
100
120
150 ns
tELQV
tCE
Chip Enable Low to
Output Valid
G = VIL
100
120
150 ns
tGLQV
tOE
Output Enable Low to
Output Valid
E = VIL
50
60
70 ns
tBLQZ (2)
tSTD
BYTE Low to Output
Hi-Z
E = VIL, G = VIL
45
50
60 ns
tEHQZ (2)
tDF
Chip Enable High to
Output Hi-Z
G = VIL
0 45 0 50 0 60 ns
tGHQZ (2)
tDF
Output Enable High to
Output Hi-Z
E = VIL
0 45 0 50 0 60 ns
tAXQX
tOH
Address Transition to
Output Transition
E = VIL, G = VIL
5
5
5
ns
tBLQX
tOH
BYTE Low to Output
Transition
E = VIL, G = VIL
5
5
5
ns
Note: 1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP
2. Sampled only, not 100% tested.
Figure 5. Word-Wide Read Mode AC Waveforms
A0-A18
E
G
Q0-Q15
Note: BYTEVPP = VIH.
6/16
VALID
tAVQV
tGLQV
tELQV
tAXQX
VALID
tEHQZ
tGHQZ
Hi-Z
AI01596B