M74HC151
Electrical characteristics
Table 8: Capacitive characteristics
Symbol Parameter
CIN
Input
capacitance
Power
CPD dissipation
capacitance(1)
Test
condition
VCC (V)
5.0
5.0
TA = 25°C
Min. Typ. Max.
Value
-40 to 85°C
Min. Max.
-55 to 125°C
Min. Max.
5
10
10
10
63
Unit
pF
pF
Notes:
(1)CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the
operating current consumption without load (refer to the test circuit). The average operating current
can be obtained by the following equation: ICC(opr) = CPD x VCC x fIN + ICC
Figure 4: Test circuit
VCC
PULSE
GENERATOR
D.U.T.
R
1
T
C
2
L
1. RT = ZOUT of pulse generator (typically 50 ohm)
2. CL = 50 pF or equivalent (includes jig and probe capacitance)
DocID001904 Rev 2