NJM2867/68
TYPICAL APPLICATION
1 In the case where ON/OFF Control is not required:
VIN
VIN
VOUT
0.1µF
R
(0~300kΩ)
NJM2867/68
CONTROL
GND
VOUT
0.1µF *5
*5 2.3V<Vo≤2.8V version: Co=0.22µF
Vo≤2.3V version: 0.47µF
Connect control terminal to VIN terminal
The quiescent current can be reduced by using a resistance “R”. Instead, it increases the minimum operating
voltage. For further information, please refer to Figure “Output Voltage vs. Control Voltage”.
2 In use of ON/OFF CONTROL:
VIN
VIN
VOUT
VOUT
0.1µF
R
NJM2867/68
CONTROL
GND
0.1µF *5
*5 2.3V<Vo≤2.8V version: Co=0.22µF
Vo≤2.3V version: 0.47µF
State of control terminal:
•“H”→ output is enabled.
•“L” or “open” → output is disabled.
-4-
Ver.2004-12-22