MYB (50/70/90A)-SERIES
MYB-1250-33
MYB-1270-33
MYB-1290-33
Ⅵ Features
(1) High attenuation effect against high voltage
pulse noise
(2) Compact and low profile (H = 65mm)
(3) Leakage current: 1mA max. (250V, 60Hz)
Ⅵ Safety standard
(1) MYB-1250-33, MYB-1290-33
Conforms to UL safety standard (UL1283)
Conforms to CSA safety standard
(CSA Std. C22. 2 No. 8)
(2) MYB-1270-33
UL1283, CSA Std. C22. 2 No. 8
Ⅵ Specifications
Item
Model
1 Rated voltage (AC, DC)
2 Rated current (AC, DC)
(Note)
3 Test voltage (terminal to case, AC 1 minute)
4 Isolation resistance (terminal to case, 500VDC)
5 Leakage current
125V, 60Hz
250V, 60Hz
6 DC resistance
7 Temperature rise
8 Operating temperature
9 Operating humidity
10 Storage temperature
11 Storage humidity
12 Vibration
13 Safety standard
14 Weight (typ)
Ⅵ Circuit
MYB-1250-33
MYB-1270-33
MYB-1290-33
250V
50A
70A
90A
2500V (25°C, 70% RH)
300MΩ min. (25°C, 70% RH)
0.5mA max.
0.1mA max.
2.5mΩ max.
1.9mΩ max.
1.3mΩ max.
35°C max
–25 ~ +85°C
30% ~ 90% RH (No dewdrop)
–30 ~ +85°C
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours
Only MYB-1270-33 is approved by UL 1283 and CSA std. C22. 2 No. 8
2000g
2900g
3000g
(Note) : Value at Ta <=50°C. Refer to the derating curve shown below at Ta > 50°C.
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.