Note 1:
Note 2:
The qualification parameters are continuously
monitored throughout the charge cycle. For more
details on this, refer to Section 4.1 “Charge
Qualification and Preconditioning”.
The charge current will be scaled based on the
die temperature during thermal regulation. For
more details, refer to Section 4.5 “Thermal
Regulation”.
Initialize
NOTE 1
VDD > VUVLO
EN High
Yes
NOTE 1 Temperature OK
Yes
Preconditioning Mode
Charge Current = IPREG
Reset Safety Timer
Yes
VBAT > VPTH
No
VBAT > VPTH
Yes
NOTE 2
Constant-current
Mode
Charge Current = IREG
Reset Safety Timer
No
STAT1 = Off
STAT2 = Off
No
STAT1 = Off
STAT2 = Flashing
Charge Current = 0
STAT1 = On
STAT2 = Off
Constant-voltage Mode
Output Voltage = VREG
VBAT = VREG
Yes
IOUT < ITERM
Elapsed Timer
Expired
Yes
Charge Termination
Charge Current = 0
Reset Safety Timer
No
No
No
Safety Timer
Expired
Yes Fault
Charge Current = 0
Reset Safety Timer
Yes
Safety Timer
Expired
Yes
Temperature OK
No
Yes
Temperature OK
VDD < VUVLO
or EN Low
No
Yes
Temperature OK
No
STAT1 = Flashing
Safety Timer Suspended
Charge Current = 0
No
STAT1 = Off
Yes
STAT2 = Flashing
Safety Timer Suspended
Charge Current = 0
No
STAT1 = Off
STAT2 = On
No
STAT1 = Off
STAT2 = Flashing
Safety Timer Suspended
Charge Current = 0
VDD < VUVLO
VBAT < VRTH
or EN Low
Yes
No
STAT1 = Flashing
STAT2 = Off
FIGURE 4-2:
Operational Flow Algorithm.