Continued from preceding page.
Number
Symbol
13
LCTR/I-7
LC72146, 72146M, 72146V
Type
Function
General-purpose
counter
• LCTR is selected when CTS1 is set to 0.
• If the CTS0 bit in the serial data is set to 1:
• The circuit operates in frequency measurement mode.
• nput frequency range: 10 to 500 kHz
• The signal is directly transmitted to the general-purpose
counter without passing through the divide-by-two circuit.
• If the CTS0 bit in the serial data is set to 0:
• The circuit operates in period measurement mode.
• nput frequency range: 1 Hz to 20 kHz
• The measurement period can be set to be either one or
two periods of the input signal, and if two period
measurement is selected, the input frequency range
becomes 2 Hz to 40 kHz.
• The result is output from the DO output pin starting with
the MSB of the general-purpose counter.
• See the item on the structure of the general-purpose
counter for details.
• When the L/I-7 bit in the serial data is set to 0:
• This pin functions as an input port. The value input is
output from the DO pin.
Equivalent circuit
S
No. 4922-8/22