READ/WRITE CYCLE SWITCHING CHARACTERISTICS (Over Operating Range)
Symbol Parameter
-250
Min. Max.
-200
Min. Max.
Unit
fMAX Clock Frequency
250
200
MHz
tKC
Cycle Time
4.0
5
ns
tKH
Clock High Time
1.7
2
ns
tKL
Clock Low Time
1.7
2
ns
tKQ
Clock Access Time
2.6
3.1
ns
tKQX(2) Clock High to Output Invalid
0.8
1.5
ns
tKQLZ(2,3) Clock High to Output Low-Z
0.8
1
ns
tKQHZ(2,3) Clock High to Output High-Z
2.6
3.0
ns
tOEQ Output Enable to Output Valid
2.8
3.1
ns
tOELZ(2,3) Output Enable to Output Low-Z
0
0
ns
tOEHZ(2,3) Output Disable to Output High-Z
2.6
3.0
ns
tAS
Address Setup Time
1.2
1.4
ns
tWS Read/Write Setup Time
1.2
1.4
ns
tCES Chip Enable Setup Time
1.2
1.4
ns
tAVS Address Advance Setup Time
1.2
1.4
ns
tDS
Data Setup Time
1.2
1.4
ns
tAH
Address Hold Time
0.3
0.4
ns
tWH
Write Hold Time
0.3
0.4
ns
tCEH Chip Enable Hold Time
0.3
0.4
ns
tAVH Address Advance Hold Time
0.3
0.4
ns
tDH
Data Hold Time
0.3
0.4
ns
tPDS ZZ High to Power Down
2
2
cyc
tPUS ZZ Low to Power Down
2
2
cyc
Note:
1. Configuration signal MODE is static and must not change during normal operation.
2. Guaranteed but not 100% tested. This parameter is periodically sampled.
3. Tested with load in Figure 2.
Integrated Silicon Solution, Inc. — 1-800-379-4774
17
Rev. N
02/12/2010

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]