IDT70121/IDT70125
High-Speed 2K x 9 Dual-Port Static RAM with Busy & Interrupt
Absolute Maximum Ratings(1)
Symbol
Rating
Commercial
Unit
& Industrial
VTERM(2)
Terminal Voltage
with Respect
to GND
-0.5 to +7.0
V
TBIAS
Temperature
Under Bias
-55 to +125
oC
TSTG
Storage
Temperature
-65 to +150
oC
IOUT
DC Output
Current
50
mA
Industrial and Commercial Temperature Ranges
Recommended DC
Operating Conditions
Symbol
Parameter
Min. Typ. Max. Unit
VCC Supply Voltage
4.5 5.0 5.5 V
GND Ground
0
0
0
V
VIH Input High Voltage
2.2
____
6.0(2)
V
VIL Input Low Voltage
-0.5(1)
____
0.8
V
NOTES:
1. VIL > -1.5V for pulse width less than 10ns.
2. VTERM must not exceed Vcc + 10%.
2654 tbl 03
NOTES:
2654 tbl 01
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only and functional Capacitance (TA = +25°C, f = 1.0MHz)
operation of the device at these or any other conditions above those indicated
in the operational sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect reliabilty.
Symbol
Parameter
Conditions(1) Max. Unit
2. VTERM must not exceed Vcc + 10% for more than 25% of the cycle time or 10ns
maximum, and is limited to < 20mA for the period of VTERM > Vcc + 10%.
CIN Input Capacitance
VIN = 3dV
9 pF
COUT Output Capacitance
VOUT = 3dV
10 pF
Maximum Operating Temperature
and Supply Voltage(1)
NOTE:
2654 tbl 04
1. This parameter is determined by device characterization but is not production
tested.
Grade
Ambient
GND
Vcc
Temperature
Commercial
0OC to +70OC
0V
5.0V + 10%
Industrial
-40OC to +85OC
0V
5.0V + 10%
NOTES:
2654 tbl 02
1. This is the parameter TA. This is the "instant on" case temperature.
DC Electrical Characteristics Over the Operating
Temperature and Supply Voltage Range (VCC = 5.0V ± 10%)
70121S
70125S
Symbol
Parameter
Test Conditions
Min.
Max.
|ILI| Input Leakage Current(1)
VCC = 5.5V, VIN = 0V to VCC
___
10
|ILO| Output Leakage Current
VCC = 5.5V, CE = VIH, VOUT = 0V to VCC
___
10
VOL Output Low Voltage
IOL = +4mA
___
0.4
VOH Output High Voltage
IOH = -4mA
2.4
___
NOTE:
1. At Vcc < 2.0V leakages are undefined.
70121L
70125L
Min.
Max. Unit
___
5
µA
___
5
µA
___
0.4
V
2.4
___
V
2654 tbl 05