POWERLINE - DC/DC-Converter
G-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Output Power
Voltage Accuracy (full Load and nominal Vin)
Single / Dual
Triple Main
Auxilliary
Voltage Adjustability (single output only)
Minimum Load Voltage (see note 1)
Single & Triple
Dual (3.3V)
Line Regulation (LL-HL at FL)
Load Regulation (10% to 100% FL)
Single
Dual
Triple
Main
Auxilliary
Ripple and Noise, 20MHz BW (measured with a 104pF/50V MLCC)
Temperature Coefficient
Transient Response Recovery Time (25% load step change)
Over Voltage Protection (zener diode clamp):
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
3.3V Output
5V Output
12V Output
15V Output
Input Voltage Range
24V types nominal input
48V types nominal input
Under Voltage Lockout
24V Input
48V Input
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Input Filter
Input Surge Voltage (100 ms max.)
24V Input
48V Input
Input Reflected Ripple (see note 2)
Nominal Vin and full load
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 3)
Remote off Input Current
DC-DC ON
DC-DC OFF
Nominal Vin
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Approved to Safety Standards
Case Material
Base Material
Potting Material
Weight
Dimensions
MTBF (MIL-HDBK-217F, TA = 25°C full load)
www.recom-international.com
August 2002
40W max.
±1%
±1%
±5%
± 10%
10% of FL
800mA
±0.5%
±0.5%
±1%
±2%
±5%
See selection guide table
±0.02%/°C max.
400µsec
3.9V
6.2V
15V
18V
150% max.
Hiccup, Automatic Recovery
18-36VDC
36-75VDC
17.8VDC
16VDC
36VDC
34VDC
L-C Type
50VDC
100VDC
40mAp-p
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
2.5 mA
1600VDC
109 Ω
1000pF
300kHz
UL 1950, EN60950
Nickel-Coated Copper
Non-conducted Black FR4
Epoxy (UL94-V0)
60g (2.11 oz)
50.8 x 50.8 x 10.2 mm
1.434 x 105 Hours
continued on next page
PO 69