First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
HT49RV3/HT49CV3
Remote Control Timer - RMT
The HT49RV3/HT49CV3 provides an 8-bit remote con-
trol timer that has a pulse width measurement function.
Pulse width is measured from a difference in count value
when the valid edge (RMT pin) has been detected while
the timer operates in the running mode.
The RMT pin with rising/falling edge wake-up function,
8-bit timer counter will be cleared during a chip reset.
And the RMT clock starts to count after the rising/falling
edge trigger.
N o is e R e je c tio n
R e m o te C o n tr o l T im e r
RM T
R is in g E d g e
C a p tu r e R e g is te r
D e te c tio n
L a tc h
R M T 0 (2 2 H )
fS Y S
fS Y S /4
M fX
U
X
fX /2 5~ fX /2 8
P r e - s c a le r
4 -1 M U X
RM CS RM S1 RM S0 RM E
8 - b it T im e r C o u n te r
C le a r
N o is e R e je c tio n L a tc h R e m o te C o n tr o l T im e r
F a llin g E d g e
C a p tu r e R e g is te r
D e te c tio n
R M T 1 (2 3 H )
In te rru p t (R M T 0 F )
O v e r flo w ( R M T V F )
In te rru p t (R M T 1 F )
Remote Control Timer
Bit No.
0
1
2
3
4
5
6~7
Label
Function
¾ Unused bit, read as ²0²
ERMT0 Controls the remote control timer rising edge interrupt (1=enable; 0=disable)
ERMT1 Controls the remote control timer falling edge interrupt (1=enable; 0=disable)
ERMTV Controls the remote control timer overflow interrupt (1=enable; 0=disable)
RME Controls the remote control timer (1=enable & start count; 0=disable & clear counter)
RMCS
RMS0
RMS1
Selects the remote control timer clock source fX (1=fSYS; 0=fSYS/4)
Selects the remote control timer clock
00=fX/25
01= fX/26
10= fX/27
11= fX/28
RMTC (21H) Register
Bit No.
0
1
2
3
4
5~7
Label
Function
RMTVF
Remote control timer overflow interrupt flag (1=indicates that an overflow has occurred; 0=in-
dicates that an overflow has not occurred)
RTF
Real time clock interrupt flag (1=indicates that an RTC interrupt has occurred; 0=indicates that
an RTC interrupt has not occurred)
RMT0F
Remote control timer rising edge interrupt flag (1=indicates that a rising edge interrupt has oc-
curred; 0=indicates that a rising edge interrupt has not occurred)
RMT1F
Remote control timer falling edge interrupt flag (1=indicates that a falling edge interrupt has
occurred; 0=indicates that a falling edge interrupt has not occurred)
ERTI Controls the Real Time Clock interrupt (1=enable; 0=disable)
¾ Unused bit, read as ²0²
MFIS (29H) Register
Rev. 1.30