White Electronic Designs
Display Systems Division
ENH050Q1-320/450/600
4. Response time is obtained by measuring the transition time of photodetector output, when input signals are applied so as to make the area
"black" from "white" and "white" from "black".
white
100%
90%
black
white
10%
0%
tr
td
time
5. Measured on th ecenter area of the panel at a viewing cone 1° by TOPCON luminance meter BM-7. (After 30 minutes operation) DC/AC inverter driving frequency : 49kHz
6. Lamp life time is defined as the time when either "a" or "b" occurs in the continuous operation under the condition of lamp current IL=3~7.
0mArms and PWM dimming 100%~5%. (tA=25°C)
a. Brightness becomes 50% of the original value.
b. Kick off voltage at tA=30°C exceeds maximum value, 1500Vrms.
7. The intermittent cycle is defined as a time when brightness becomes 50% of the original value under the condition of following cycle.
Ambient temperature: -30°C
HIGH (6.5mArms)
5 min. 5 min. 5 min. 5 min.
OFF
White Electronic Designs Corp. reserves the right to change products or specifications without notice.
Original specifications created by Sharp.
August 2003
Rev. 0
8
Display Systems Division • Hillsboro, OR • (503) 690-2460 • www.wedc.com