datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

LXR1601-6G 查看數據表(PDF) - Power-One Inc.

零件编号
产品描述 (功能)
生产厂家
LXR1601-6G Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
X Series Data Sheet
®
375, 500 Watt AC-DC and DC-DC DIN-Rail Converters
Models with four powertrains have one or two outputs.
Double-output models exhibit individual control of each
output.
The input voltage is fed via fuse, filter, and rectifier to the
powertrains with main transformers designed in planar
technique. The input filter with very small input capacitance
generates virtually no inrush current. An input transient
suppressor protects the converter against high voltage peaks
and surges. Input over- and undervoltage lockout as well as
input current limitation protect the converter from operation
outside of its specification. The input voltage waveform is
sensed by the primary control logic to allow active power
factor correction, forcing the input current to follow the input
voltage waveform.
The secondary side of each main transformer supplies via the
rectifier diode a large electrolytic output storage capacitor
providing for the hold-up time. Double-output models exhibit
an individual control logic for each output. The output voltage
and the output current are measured and fed back to the
primary control logic via an optocoupler. A second control loop
monitors the output voltage. It disables the output in the case of
a failure in the control logic and limits the output voltage.
Built-in temperature sensors monitor the internal temperature of
each powertrain. If the temperature exceeds the limit, the
converter reduces the output power continuously to keep the
temperature below its limit. A green LED on the front cover
confirms the presence of the output voltage(s).
The R input (option R, M1, or M2) allows for external adjustment
of the output voltage by means of a resistor or an external
voltage source. An external sensor can be connected to the R
input and allows for temperature-controlled battery charging;
see Accessories.
Electrical Input Data
General conditions:
TA = 25 °C, unless TC is specified.
Table 3: Input data LW models
Input
Characteristic
Vi
Operating input voltage
range
Vi nom Rated input volt. range
fi
Rated input frequency1
Ii
Input current
Pi0
I inrush
Ci
PF
Vi RFI
No-load input power
Inrush current
Input capacitance
Power factor
Conducted input RFI
Radiated input RFI
Conditions
Io = 0 – Io nom
Tc Tc max
I o nom, Vi = Vi nom
I o nom, Vi = Vi min
Vi min Vi max
Vi max , t > 0.1 ms
Vi nom = 230 V, Io nom
EN 55011/55022
Vi nom, Io nom
LXR
LXN
Unit
AC-Input
DC-Input
AC-Input
DC-Input
min typ max min typ max min typ max min typ max
85 2
264 90 2
350 3 85 2
264 90 2
350 3 V
100 (230) 240
220
100 (230) 240
220
50 – 60
--
50 60
--
Hz
1.9
1.95
2.6
5.2
5.0
7.0
2.6
A
6.6
3
3
3
3
W
5
5
5
5
A
5
5
6
6
µF
0.90
--
0.90
--
A
A
A
A
fswitch Switching frequency
130
130
130
130
kHz
1 For operating frequencies <47 Hz and >63 Hz contact Power-One. The converters have been tested up to 440 Hz.
2 Output power derating at low input voltage and/or high case temperature TC; see Output Power Derating.
3 Vi 250 VDC for models with option F.
BCD20021-G Rev AC1, 13-May-2013
Page 5 of 21
www.power-one.com

Share Link: 