datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

DS1374U-33 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
DS1374U-33 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
I2C, 32-Bit Binary Counter Watchdog RTC with
Trickle Charger and Reset Input/Output
POWER-UP/POWER-DOWN CHARACTERISTICS
(TA = -40°C to +85°C) (Figure 3)
PARAMETER
SYMBOL
CONDITIONS
VCC Detect to Recognize Inputs
(VCC Rising)
VCC Fall Time; VPF(MAX) to
VPF(MIN)
VCC Rise Time; VPF(MIN) to
VPF(MAX)
tRPU (Note 24)
tF
tR
MIN TYP MAX UNITS
250
ms
300
μs
0
μs
WARNING: Under no circumstances are negative undershoots, of any amplitude, allowed when the device is in write protection.
Note 2: Limits at -40°C are guaranteed by design and not production tested.
Note 3: All voltages are referenced to ground.
Note 4: VBACKUP should not exceed VCC MAX or 3.7V, whichever is greater.
Note 5: The use of the 250Ω trickle-charge resistor is not allowed at VCC > 3.63V and should not be enabled.
Note 6: Measured at VCC = typ, VBACKUP = 0V, register 09h = A5h.
Note 7: Measured at VCC = typ, VBACKUP = 0V, register 09h = A6h.
Note 8: Measured at VCC = typ, VBACKUP = 0V, register 09h = A7h.
Note 9: SCL only.
Note 10: SDA and SQW and INT.
Note 11: The RST pin has an internal 50kΩ pullup resistor to VCC.
Note 12: Trickle charger disabled.
Note 13: ICCA—SCL clocking at max frequency = 400kHz.
Note 14: Specified with I2C bus inactive.
Note 15: Measured with a 32.768kHz crystal attached to the X1 and X2 pins.
Note 16: WDSTR = 1. BBSQW = 1 is required for operation when VCC is below the power-fail trip point (or absent).
Note 17: CB—total capacitance of one bus line in pF.
Note 18: After this period, the first clock pulse is generated.
Note 19: The maximum tHD:DAT only has to be met if the device does not stretch the low period (tLOW) of the SCL signal.
Note 20: A device must internally provide a hold time of at least 300ns for the SDA signal (referred to as the VIHMIN of the SCL sig-
nal) to bridge the undefined region of the falling edge of SCL.
Note 21: A fast-mode device can be used in a standard-mode system, but the requirement tSU:DAT to 250ns must be met. This is
automatically the case if the device does not stretch the low period of the SCL signal. If such a device does stretch the low
period of the SCL signal, it must output the next data bit to the SDA line tR max + tSU:DAT = 1000 + 250 = 1250ns before
the SCL line is released.
Note 22: Guaranteed by design. Not production tested.
Note 23: The parameter tOSF is the period of time the oscillator must be stopped for the OSF flag to be set over the voltage range of
0V VCC VCC MAX and 1.3V VBACKUP 3.7V.
Note 24: This delay applies only if the oscillator is enabled and running. If the EOSC bit is 1, the startup time of the oscillator is
added to this delay.
_____________________________________________________________________ 5

Share Link: 