datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

CS5102A(1995) 查看數據表(PDF) - Cirrus Logic

零件编号
产品描述 (功能)
生产厂家
CS5102A
(Rev.:1995)
Cirrus-Logic
Cirrus Logic 
CS5102A Datasheet PDF : 40 Pages
First Prev 31 32 33 34 35 36 37 38 39 40
CS5101A CS5102A
Power Supply Connections
VD+ - Positive Digital Power, PIN 7.
Positive digital power supply. Nominally +5 volts.
VD- - Negative Digital Power, PIN 1.
Negative digital power supply. Nominally -5 volts.
DGND - Digital Ground, PIN 6.
Digital ground [reference].
VA+ - Positive Analog Power, PIN 25.
Positive analog power supply. Nominally +5 volts.
VA- - Negative Analog Power, PIN 23.
Negative analog power supply. Nominally -5 volts.
AGND - Analog Ground, PIN 22.
Analog ground reference.
Oscillator
CLKIN - Clock Input, PIN 3.
All conversions and calibrations are timed from a master clock which can be externally
supplied by driving CLKIN [this input TTL-compatible, CMOS recommended].
XOUT - Crystal Output, PIN 4.
The master clock can be generated by tying a crystal across the CLKIN and XOUT pins. If an
external clock is used, XOUT must be left floating.
Digital Inputs
HOLD - Hold, PIN 12.
A falling transition on this pin sets the CS5101A or CS5102A to the hold state and initiates a
conversion. This input must remain low for at least 1/tclk + 20 ns. When operating in Free Run
Mode, HOLD is disabled, and should be tied to DGND or VD+.
CRS/FIN - Coarse Charge/Fine Charge Control, PIN 10.
When brought high during acquisition time, CRS/FIN forces the CS5101A or CS5102A into
coarse charge state. This engages the internal buffer amplifier to track the analog input and
charges the capacitor array much faster, thereby allowing the CS5101A or CS5102A to track
high slewing signals. In order to get an accurate sample, the last coarse charge period before
initiating a conversion (bringing HOLD low) must be longer than 0.75 µs (CS5101A) or
3.75 µs (CS5102A). Similarly, the fine charge period immediately prior to conversion must be
at least 1.125 µs (CS5101A) or 5.625 µs (CS5102A). The CRS/FIN pin must be low during
conversion time. For normal operation, CRS/FIN should be tied low, in which case the
CS5101A or CS5102A will automatically enter coarse charge for 6 clock cycles immediately
after the end of conversion.