CAT5120, CAT5121, CAT5122
Table 3. ELECTRICAL CHARACTERISTICS
(VDD = 2.7 V to 5.5 V, VH = VDD, VL = 0, TA = −40°C to +85°C. Typical values are at VDD = 2.7 V, TA = 25°C, unless otherwise noted.)
Parameter
Symbol
Conditions
Min
Typ
Max
Units
DC PERFORMANCE
Resolution
16
Taps
End−to−End Resistance (−00)
75
100
125
kW
End−to−End Resistance (−50)
37.5
50
62.5
End−to−End Resistance (−10)
7.5
10
12.5
End−to−End Resistance Tempco
TCR
Ratiometric Resistance Tempco
200
ppm/°C
5
ppm/°C
Integral Nonlinearity
INL
±0.5
LSB
Differential Nonlinearity
DNL
±0.5
LSB
Zero/Full−Scale Error
±0.1
±0.5
LSB
Wiper Resistance
RW
DIGITAL INPUTS
200
600
W
Input High Voltage
VIH
Input Low Voltage
VIL
TIMING CHARACTERISTICS (Figures 7, 8)
0.7 x VDD
V
0.3 x VDD
V
U/D Mode to CS Setup
CS to U/D Step Setup
CS to U/D Step Hold
U/D Step Low Period
U/D Step High Period
Up/Down Toggle Rate (Note 2)
Output Settling Time (Note 3)
tCU
25
tCI
50
tIC
25
tIL
25
tIH
25
fTOGGLE
1
tSETTLE
100 kW variable resistor
1
configuration, CL = 10 pF
ns
ns
ns
ns
ns
MHz
ms
100 kW potentiometer
0.25
configuration, CL = 10 pF
POWER SUPPLY
Supply Voltage
VDD
Active Supply Current (Note 4)
IDD
Standby Supply Current (Note 5)
ISB
VDD = +5 V
2. Up/Down Toggle Rate: fTOGGLE = 1 / tSETTLE
3. Typical settling times are dependent on end−to−end resistance.
4. Supply current measured while changing wiper tap, fTOGGLE = 1 MHz.
5. Supply current measured while wiper position is fixed.
2.7
5.5
V
25
mA
0.3
1
mA
http://onsemi.com