Figure 11. Application Example
Note 1:
For optimum fractional spur and lock-time performance C2 and C5 should be polyester (or poly
propylene). In addition, the loop filter components must be free from contamination. Contamination
will result in poor spur performance. For accurate loop bandwidth, C1 must be greater than or equal to
100 pF, and C4 must be greater than or equal to 200 pF.