datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MT28C3214P2FL-10T 查看數據表(PDF) - Micron Technology

零件编号
产品描述 (功能)
生产厂家
MT28C3214P2FL-10T
Micron
Micron Technology 
MT28C3214P2FL-10T Datasheet PDF : 42 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
2 MEG x 16 PAGE FLASH
256K x 16 SRAM COMBO MEMORY
CLEAR STATUS REGISTER
The internal circuitry can set, but not clear, the block
lock status bit (SR1), the VPP status bit (SR3), the pro-
gram status bit (SR4), and the erase status bit (SR5) of
the status register. The CLEAR STATUS REGISTER com-
mand (50h) allows the external microprocessor to clear
these status bits and synchronize to the internal op-
erations. When the status bits are cleared, the device
returns to the read array mode.
READ OPERATIONS
The following READ operations are available: READ
ARRAY, READ PROTECTION CONFIGURATION REG-
ISTER, READ QUERY and READ STATUS REGISTER.
READ ARRAY
The array is read by entering the command code
FFh on DQ0–DQ7. Control signals F_CE# and F_OE#
must be at a logic LOW level (VIL), and F_WE# and F_RP#
must be at a logic HIGH level (VIH) to read data from the
array. Data is available on DQ0–DQ15. Any valid ad-
dress within any of the blocks selects that address and
allows data to be read from that address. Upon initial
power-up, the device defaults to the read array mode.
READ CHIP PROTECTION IDENTIFICATION DATA
The chip identification mode outputs three types
of information: the manufacturer/device identifier, the
block locking status, and the protection register. Two
bus cycles are required for this operation: the chip iden-
tification data is read by entering the command code
90h on DQ0–DQ7 to the bank containing address 00h
and the identification code address on the address
lines. Control signals F_CE# and F_OE# must be at a
logic LOW level (VIL), and F_WE# and F_RP# must be at
a logic HIGH level (VIH) to read data from the protection
configuration register. Data is available on DQ0–DQ15.
After data is read from the protection configuration
register, the READ ARRAY command, FFh, must be is-
sued to the bank containing address 00h prior to issu-
ing other commands. See Table 10 for further details.
READ QUERY
The read query mode outputs common flash inter-
face (CFI) data when the device is read (see Table 12).
Two bus cycles are required for this operation. It is
possible to access the query by writing the read query
command code 98h on DQ0–DQ7. Control signals
F_CE# and F_OE# must be at a logic LOW level (VIL),
and F_WE# and F_RP# must be at a logic HIGH level
(VIH) to read data from the query. The CFI data struc-
ture contains information such as block size, density,
command set, and electrical specifications. To return
to read array mode, write the read array command code
FFh on DQ0–DQ7.
READ STATUS REGISTER
The status register is read by entering the command
code 70h on DQ0–DQ7. Two bus cycles are required for
this operation: one to enter the command code and a
second to read the status register. In a READ cycle, the
address is latched and register data is updated on the
falling edge of F_OE# or F_CE#, whichever occurs last.
2 Meg x 16 Page Flash 256K x 16 SRAM Combo Memory
MT28C3214P2FL_4.p65 – Rev. 4, Pub. 4/02
14
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2002, Micron Technology, Inc.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]