APL3218
Operating Waveforms
Refer to the typical application circuit. The test condition is VIN=5V, TA= 25oC unless otherwise specified.
Current Limit Protection
VACIN
VCHR _LDO
1
2
VVCDT
3
I OUT
Over-Current Trip Threshold
Current Limit
4
CACIN=1µF, CCHR_LDO=1µF, IOUT=0.5A to 1.6A
GATDRV tied to GND.
CH1: VACIN, 5V/Div, DC
CH2: VCHR_LDO, 5V/Div, DC
CH3: VCDT, 0.5V/Div, DC
CH4: IOUT, 0.5A/Div, DC
TIME: 200µs/Div
Input Line Transient Response
V ACIN
1
V CHR _LDO
LDO Mode
2
V VCDT
3
CACIN=1µF, CCHR_LDO=1µF, VACIN=5V→9V→5V.
CH1: VACIN, 5V/Div, DC
CH2: VCHR_LDO, 2V/Div, DC
CH3: VCDT, 0.5V/Div, DC
TIME: 10ms/Div
Copyright © ANPEC Electronics Corp.
8
Rev. A.1 - Apr., 2012