Philips Semiconductors
CMOS single-chip 8-bit microcontrollers
Product specification
80C32/87C52
Electrical Deviations from Commercial Specifications for Extended Temperature Range (87C52)
DC and AC parameters not included here are the same as in the commercial temperature range table.
DC ELECTRICAL CHARACTERISTICS
Tamb = –40°C to +85°C, VCC = 5V ±10%, VSS = 0V
SYMBOL
VIL
VIL1
VIH
VIH1
IIL
ITL
ICC
PARAMETER
Input low voltage, except EA
Input low voltage to EA
Input high voltage, except XTAL1, RST
Input high voltage to XTAL1, RST
Logical 0 input current, ports 1, 2, 3
Logical 1-to-0 transition current, ports 1, 2, 3
Power supply current:
Active mode
Idle mode
Power-down mode
TEST
CONDITIONS
VIN = 0.45V
VIN = 2.0V
VCC = 4.5–5.5V,
Frequency range =
3.5 to 16MHz
LIMITS
MIN
MAX
–0.5
0
0.2VCC+1
0.7VCC+0.1
0.2VCC–0.15
0.2VCC–0.35
VCC+0.5
VCC+0.5
–75
–750
32
5
50
UNIT
V
V
V
V
µA
µA
mA
mA
µA
ABSOLUTE MAXIMUM RATINGS1, 2, 3
PARAMETER
RATING
UNIT
Operating temperature under bias
0 to +70 or –40 to +85
°C
Storage temperature range
–65 to +150
°C
Voltage on EA/VPP pin to VSS
0 to +13.0
V
Voltage on any other pin to VSS
–0.5 to +6.5
V
Maximum IOL per I/O pin
15
mA
Power dissipation (based on package heat transfer limitations, not
device power consumption)
1.5
W
NOTES:
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any conditions other than those described in the AC and DC Electrical Characteristics section
of this specification is not implied.
2. This product includes circuitry specifically designed for the protection of its internal devices from the damaging effects of excessive static
charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying greater than the rated maxima.
3. Parameters are valid over operating temperature range unless otherwise specified. All voltages are with respect to VSS unless otherwise
noted.
1996 Aug 16
13

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]