NXP Semiconductors
74LVC1G53
2-channel analog multiplexer/demultiplexer
Table 7. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground 0 V).
Symbol Parameter Conditions
−40 °C to +85 °C
Min Typ[1] Max
CI
input
capacitance
-
2.5
-
CS(OFF) OFF-state
capacitance
-
6.0
-
CS(ON) ON-state
capacitance
-
18
-
[1] Typical values are measured at Tamb = 25 °C.
[2] These typical values are measured at VCC = 3.3 V
−40 °C to +125 °C
Min
Max Unit
-
- pF
-
- pF
-
- pF
10.1 Test circuits
VIL or VIH
VIH
VI
VCC
S
Y0 1
switch
Z
Y1 2
IS
E
GND
VI = VCC or GND; VO = GND or VCC.
Fig 6. Test circuit for measuring OFF-state leakage current
switch S
E
1
VIH VIH
2
VIL VIH
VO
001aad390
VIL or VIH
IS
VIL
VI
VCC
S
Z
E
Y0 1
Y1 2
switch
GND
switch S
E
1
VIH VIL
2
VIL VIL
VO
VI = VCC or GND and VO = open circuit.
Fig 7. Test circuit for measuring ON-state leakage current
001aad391
74LVC1G53_3
Product data sheet
Rev. 03 — 29 August 2007
© NXP B.V. 2007. All rights reserved.
6 of 22