Philips Semiconductors
16-channel analog
multiplexer/demultiplexer
Product specification
74HC/HCT4067
DC CHARACTERISTICS FOR 74HC/HCT
For 74HC: VCC − GND = 2.0, 4.5, 6.0 and 9.0 V
For 74HCT: VCC − GND = 4.5 V
Tamb (°C)
TEST CONDITIONS
SYMBOL PARAMETER
74HC/HCT
+25
−40 to +85
−40 to +125
UNIT VCC
(V)
IS
(µA)
Vis
VI
min. typ. max. min. max. min. max.
RON
ON-resistance
(peak)
−
−
−
110 180
225
95 160
200
75 130
165
RON
ON-resistance (rail)
150 −
−
90 160
200
80 140
175
70 120
150
∆RON
maximum variation
−
of ON-resistance
9
between any two
8
channels
6
−
Ω
270 Ω
240 Ω
195 Ω
−
Ω
240 Ω
210 Ω
180 Ω
Ω
Ω
Ω
Ω
2.0 100 VCC VIH
4.5 1000 to or
6.0 1000 GND VIL
9.0 1000
2.0 100 GND VIH
4.5 1000 or or
6.0 1000 VCC VIL
9.0 1000
2.0
VCC VIH
4.5
to or
6.0
GND VIL
9.0
Notes
1. At supply voltages (VCC − GND) approaching 2 V, the analog switch ON-resistance becomes extremely non-linear.
Therefore it is recommended that these devices be used to transmit digital signals only, when using these supply
voltages.
2. For test circuit measuring RON see Fig.7.
Fig.7 Test circuit for measuring ON-resistance (RON).
September 1993
Fig.8 Test circuit for measuring OFF-state current.
7