Industrial Version
PLCC DC Electrical Characteristics (Note 7)
VEE = −4.2V to −5.7V, VCC = VCCA = GND, TC = −40°C to +85°C
Symbol
Parameter
TC = −40°C
Min
Max
TC = 0°C to +85°C
Min
Max
Units
Conditions
VOH
VOL
VOHC
VOLC
VIH
VIL
IIL
IIH
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input LOW Current
Input HIGH Current
−1085
−1830
−1095
−1170
−1830
0.50
−870
−1575
−1565
−870
−1480
−1025
−1830
−1035
−1165
−1830
0.50
−870
−1620
−1610
−870
−1475
Data
350
350
Enable
240
240
mV
VIN = VIH(Max)
or VIL(Min)
Loading with
50Ω to −2.0V
mV
VIN = VIH(Min)
or VIL(Max)
Loading with
50Ω to −2.0V
mV Guaranteed HIGH Signal for All Inputs
mV Guaranteed LOW Signal for All Inputs
µA
VIN = VIL(Min)
µA
VIN = VIH(Max)
IEE
Power Supply Current
−59
−29
−59
−29
mA Inputs OPEN
Note 7: The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
PLCC AC Electrical Characteristics
VEE = −4.2V to −5.7V, VCC = VCCA = GND
Symbol
Parameter
TC = −40°C
Min
Max
TC = +25°C
Min
Max
TC = +85°C
Min
Max
Units
tPLH
Propagation Delay
tPHL
Data to Output
0.55
1.20
0.55
1.20
0.55
1.30
ns
tPLH
Propagation Delay
tPHL
Enable to Output
0.80
1.70
0.80
1.70
0.80
1.80
ns
tTLH
Transition Time
tTHL
20% to 80%, 80% to 20%
0.45
1.30
0.45
1.30
0.45
1.30
ns
Note 8: The propagation delay specified is for single output switching. Delays may vary up to 150 ps with multiple outputs switching.
Conditions
Figures 1, 2
(Note 8)
Figures 1, 2
5
www.fairchildsemi.com