CMON:
Current monitoring is a read only data. It is ranged from 0% to 100% of rated IO. The output current of module can be
calculated by the equation below:
Receive Data (from module to PC):
Input Data: MCU Cmon (round to 1 decimal place)
Output Data: Output Current Monitor in % IO max (integer)
Output Current Monitor in %Iomax = MCU Cmon ×100%
614
DEFAULT FACTORY SETTING
Control data
Slave address
OVP_ADJ
V_ADJ
CLIM_ADJ
Factory Setting
0010100000 (A0h = 160) (8 bit addressing)
0011001101 (00CDh = 205) (125% of VO)
0011001101 (00CDh = 205) (100% of VO (nom) )
1111111111 (0349h = 841) (110% of rated IO)