AD1859
ABSOLUTE MAXIMUM RATINGS*
DVDD to DGND
AVDD to AGND
Digital Inputs
Analog Inputs
AGND to DGND
Reference Voltage
Soldering
Min
Typ
Max
–0.3
6
–0.3
6
DGND – 0.3
AGND – 0.3
–0.3
DVDD + 0.3
AVDD + 0.3
0.3
Indefinite Short Circuit to Ground
+300
10
Units
V
V
V
V
V
°C
sec
*Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
DIGITAL FILTER CHARACTERISTICS
Min
Typ
Max
Units
Passband Ripple
Stopband1 Attenuation
48 kHz FS
Passband
Stopband
44.1 kHz FS
Passband
Stopband
32 kHz FS
Passband
Stopband
Other FS
Passband
Stopband
Group Delay
Group Delay Variation
62
0
26.688
0
24.520
0
17.792
0
0.556
± 0.045
dB
dB
21.312
kHz
6117
kHz
19.580
kHz
5620
kHz
14.208
kHz
4078
kHz
0.444
FS
127.444
FS
40/FS
sec
0
µs
ANALOG FILTER CHARACTERISTICS
Passband Ripple
Stopband Attenuation (at 64 × FS)
Min
Typ
Max
Units
–0.075
dB
58
dB
NOTE
1Stopband nominally repeats itself at multiples of 128 × FS, where FS is the input word rate. Thus the digital filter will attenuate to 62 dB across the frequency
spectrum except for a range ± 0.55 × FS wide at multiples of 128 × FS.
PIN CONNECTIONS
ORDERING GUIDE
Model
Temperature
Range
Package
Description
Package
Option
AD1859JR –40°C to +105°C 28-Lead SOIC R-28
AD1859JRS –40°C to +105°C 28-Lead SSOP RS-28
CMOUT 1
28 FILT
DEEMP 2
EMPL 3
OUTL 4
27 FGND
26 EMPR
25 OUTR
NC 5
24 NC
AGND 6
23 AVDD
AD1859
MUTE 7
22 NC
TOP VIEW
18/16 8 (Not to Scale) 21 CLATCH
IDPM0 9
20 CDATA
IDPM1 10
PD/RST 11
19 CCLK
18 DGND
SDATA 12
LRCLK 13
BCLK 14
17 DVDD
16 XTALI/MCLK
15 XTALO
NC = NO CONNECT
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD1859 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. A