Ericsson
Description
The PBL 386 65/2 Subscriber Line Interface Circuit (SLIC) is a 90 V bipolar integrated circuit for use in DLC, Central Office and other telecommunications equipment. The PBL 386 65/2 has been optimized for low total line interface cost and a high degree of flexibility in different applications.
KEY FEATUREs
• Selectable overhead voltage principle
– All adaptive: The overhead voltage follows 0.6 PeakV < signals < 6.2VPeak.
– Semi adaptive: The overhead voltage follows 3.1V Peak < signals < 6.2VPeak.
• Metering 2.2 Vrms
• High and low battery with automatic switching
• Battery supply as low as -10 V
• Only +5 V in addition to GND and battery (VEE optional)
• 39 mW on-hook power dissipation in active state
• Long loop battery feed tracks VBat for maximum line voltage
• 44V open loop voltage @ -48V battery feed
• Constant loop voltage for line leakage <5 mA
• On-hook transmission
• Full longitudinal current capability during on-hook
• Programmable loop & ring-trip detector threshold
• Ground key detector
• Analog temperature guard
• Tip open state with ring ground detector
• Silent polarity reversal
• Line voltage measurement
• -40° C to +85° C ambient temperature range