General Description
The MAX3054/MAX3055/MAX3056 are interfaces between the protocol controller and the physical wires of the bus lines in a controller area network (CAN). The devices provide differential transmit capability and switch to single-mode if certain fault conditions occur. The MAX3054/MAX3055/MAX3056 guarantee full wakeup capability during failure modes.
FEATUREs
● ±80V Fault Protection
● Low RFI/Excellent EMC Immunity
● Full Wake-Up Capability During Failure Modes
● Bus Failure Management
● Support Single-Wire Transmission Mode with Ground Offset Voltages Up to 1.5V
● Thermally Protected
● Do Not Disturb the Bus Line when Unpowered
● Low-Current Sleep and Standby Mode with Wake-Up Through Bus Lines
● Up to 250kbps Data Rate (MAX3054)
● Pin and Functionally Compatible with TJA1054
APPLICATIONs
● Industrial HVAC