LTC6990
APPLICATIONS INFORMATION
Modulation Bandwidth and Settling Time
The LTC6990 will respond to changes in ISET up to a –3dB
bandwidth of 0.4 • fOUT (see Figure 15). This makes it easy
to stabilize a feedback loop around the LTC6990, since it
does not introduce a low-frequency pole.
Settling time depends on the master oscillator frequency.
Following a 2x or 0.5x step change in ISET, the output
frequency takes approximately six master clock cycles
(6 • tMASTER) to settle to within 1% of the final value. An
example is shown in Figure 16.
0
VCTRL = 0.536V + 0.278V
• SIN(2π•fMOD•t)
fOUT =18.75kHz ±10%
–10
–3dB AT 0.4•fOUT
–20
Power Supply Current
The power supply current varies with frequency, supply
voltage and output loading. It can be estimated under any
condition using the following equation:
IS(TYP) ≈ V+• fMASTER • 7pF + V+• f OUT•(13pF + CLOAD)
+
V+
480kΩ
+
2
•
V+
RLOAD
+
1.75
•ISET
+
50µA
The equation is also valid for OE = 0 (output disabled),
with fOUT = 0Hz.
VCTRL
2V/DIV
OUT
2V/DIV
–30
RSET = 200k
RVCO = 464k
DIVCODE = 4(÷16)
–40
0.1
1
fMOD/fOUT (Hz/Hz)
10
6990 F15
Figure 15. Modulation Frequency Response
fOUT
50kHz/DIV
10µs/DIV
V+ = 3.3V, DIVCODE = 0
RSET = 200k, RVCO = 464k
fOUT = 175kHz AND 350kHz
Figure 16. Settling Time
6990 F16