TSL2671− AbsoluteMaximumRatings
Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or
any other conditions beyond those indicated under
Recommended Operating Conditions is not implied. Exposure
to absolute-maximum-rated conditions for extended periods
may affect device reliability.
Figure 5:
Absolute Maximum Ratings Over Operating Free-Air Temperature Range (unless otherwise noted)
Symbol
VDD(1)
VO
IO
TSTRG
ESDHBM
Parameter
Supply voltage
Digital output voltage range
Digital output current
Storage temperature range
ESD tolerance, human body model
Min
Max
3.8
-0.5
3.8
-1
+20
-40
85
±2000
Units
V
V
mA
°C
V
Note(s):
1. All voltages are with respect to GND.
Figure 6:
Recommended Operating Conditions
Parameter
Supply voltage, VDD
Supply voltage accuracy, VDD total error including transients
Operating free-air temperature, TA
Min
Nom
Max Units
2.6
3
3.6
V
-3
3
%
-30
70
°C
Page 6
Document Feedback
ams Datasheet
[v1-00] 2016-Jul-12